Ventilation Solutions Radon Mitigation The next step in radon fan evolution.
| Ventilation Solutions for Radon Mitigation 1 HP 190SLQ Radon Exhaust Fan 120V, 82W, 133 cfm @ 0.5" SP, max SP=2.14" The fan and discharge pipe are located on surface of the exterior wall eliminating need for elbows. The fan connects directly to a 4" pipe. NOTE: Installations that will result in condensate forming in the outlet ducting should have a condensate bypass installed to route the condensate outside of the fan housing.
Ventilation Solutions for Radon Mitigation | 3 2 HP 2190 Radon Exhaust Fan 120V, 58W, 216 cfm @ 0.5" SP, max SP=1.98" Ideally tailored performance curve for the vast majority of your mitigations. Radon Exhaust in a Single Family Home Radon comes from the natural (radioactive) breakdown of uranium in soil, bedrock and water and mixes with the air you breathe. Radon exists everywhere and no building type is immune to the potential for unhealthy radon levels.
| Ventilation Solutions for Radon Mitigation New Design We moved things around to optimize airflow, reduce noise and vibration, and increase structural integrity. Guaranteed Airtight The only radon fan that uses a vibration weld to permanently join the housing into a single piece. No caulk or sealant means no leaks. Fit optimized Collar New collar is sized specifically to fit securely on a standard radon coupler.
RADON FAN Ventilation Solutions for Radon Mitigation | 5
| Ventilation Solutions for Radon Mitigation Inline Radon Fans HP and FR Series • UV resistant, UL Listed durable plastic • UL Listed for outdoor use • Automatic reset thermal overload protection Application • Vibration welded seam ensures leak proof housing HP & FR Series fans are specially designed with higher pressure capabilities for radon mitigation applications.
Ventilation Solutions for Radon Mitigation | 7 Installation kits Kits include a pair of flexible white couplings with stainless steel hose clamps, a U-tube manometer and radon system labels.
| Ventilation Solutions for Radon Mitigation Flexible coupling and integrated condensate bypass Included coupling isolates vibration from the system pipe. Condensate bypasses the motor and drains out from the bottom of the housing. NEW INSTALLATION METHOD Model is now fully secured in place by its connections to the pipe. The flexible couplings isolate the fan’s housing from the pipe, and there is no direct attachment of the fan to the building.
Ventilation Solutions for Radon Mitigation | 9 FLEXIBLE SLEEVE COUPLING Included sleeve connects the fan to the pipe in the wall and isolates the fan's natural vibration from the pipe and building structure.
| Ventilation Solutions for Radon Mitigation Slimline Radon Fan HP 190SLQ • Inconspicuous appearance • Factory sealed, no leak design • Integral condensate bypass Application • Exterior-mount close to the wall A radon fan doesn't have to look industrial to be effective! Model HP 190SLQ is engineered specifically for the demands of radon mitigation applications with aesthetics in mind.
Ventilation Solutions for Radon Mitigation | 11 Dimensions D C B fantech E A Model A B C D HP 190SLQ 14 15/ 15 7/ 13 7/ 5 1/ 16 Dimensional information is in inches. 8 8 E 2 6 1/ 8 Installation kits FRIK SLQ installation kit includes the U-tube manometer and radon system labels only.
| Ventilation Solutions for Radon Mitigation What if a simple ASD system isn't the answer? Radon levels in certain regions or building styles can be hard to mitigate with a traditional Active Soil Depressurization (ASD) system. A Fantech HRV or ERV can be an effective way to reduce radon levels, by providing a balanced ventilation to the space, introducing fresh air and diluting the air inside the structure. In most cases, this reduces radon levels and raises overall Indoor Air Quality (IAQ).
Ventilation Solutions for Radon Mitigation | 13 Fantech® manufactures an extensive range of ventilation products, beginning with our industry first centrifugal inline fan to a wide range of commercial fans. We also manufacture a high quality range of residential and light commercial HRV/ERVs, as well as, a full complement of air terminal devices, controls, and accessories. Our products can be installed in a variety of applications from condos to large commercial projects.
| Ventilation Solutions for Radon Mitigation Quality products from the leader in ventilation HRV/ERV product range VHR 2005R 201 cfm at 0.4" SP, recirculation, shipping weight 66 lbs, art. #40063 SHR 3005R 249 cfm at 0.4" SP, recirculation, shipping weight 125 lbs, art. #40214 FLEX 100H 109 cfm at 0.4" SP, recirculation, shipping weight 46 lbs, art.
Ventilation Solutions for Radon Mitigation | 15 VHR 150 | VHR 150R 160 cfm (both at 0.4" SP), recirculation (R-version), shipping weight 48 lbs (both), art. #44921 | #44859 VHR 2004 201 cfm at 0.4" SP, recirculation, shipping weight 66 lbs, art. #40061 | SHR 1505R | SHR 2005R | SHR 3205RD SHR 1504 | SHR 2004 | SER 1504 | SER 2004 | SER 3204D 149 cfm | 201 cfm | 134 cfm | 189 cfm | 231 cfm (all at 0.4" SP) shipping weight 52 lbs | 61 lbs | 49 lbs | 66 lbs | 80 lbs art.
Customer Support: 800.747.1762 USsupport@fantech.net Send Orders: 800.487.9915 USorders@fantech.net Fantech reserves the right to modify, at any time and without notice, any or all of its products’ features, designs, components and specifications to maintain their technological leadership position. The application rendering presented in this brochure is for visual presentation purposes only. Please, contact a building professional for technical guidance. Systemair Inc. • April, 2016 • Art.