Specification

DURING ENTIRE WARRANTY PERIOD:
FANTECH will replace any fan which has a factory defect in workmanship or
material. Product may need to be returned to the Fantech factory, together with a
copy of the bill of sale and identified with RMA number.
FOR FACTORY RETURN YOU MUST:
Have a Return Materials Authorization (RMA) number. This may be obtained by calling FANTECH
either in the USA at 1.800.747.1762 or in CANADA at 1.800.565.3548. Please have bill of sale available.
The RMA number must be clearly written on the outside of the carton, or the carton will be refused.
All parts and/or product will be repaired/replaced and shipped back to buyer; no credit will be issued.
OR
The Distributor may place an order for the warranty fan and is invoiced.
The Distributor will receive a credit equal to the invoice only after product is returned prepaid and veri-
fied to be defective.
FANTECH WARRANTY TERMS DO NOT PROVIDE FOR REPLACEMENT WITHOUT CHARGE PRIOR TO
INSPECTION FOR A DEFECT. REPLACEMENTS ISSUED IN ADVANCE OF DEFECT INSPECTION ARE
INVOICED, AND CREDIT IS PENDING INSPECTION OF RETURNED MATERIAL. DEFECTIVE MATERIAL
RETURNED BY END USERS SHOULD NOT BE REPLACED BY THE DISTRIBUTOR WITHOUT CHARGE TO
THE END USER, AS CREDIT TO DISTRIBUTORS ACCOUNT WILL BE PENDING INSPECTION AND VERIFI-
CATION OF ACTUAL DEFECT BY FANTECH.
THE FOLLOWING WARRANTIES DO NOT APPLY:
Damages from shipping, either concealed or visible. Claim must be filed
with freight company.
Damages resulting from improper wiring or installation.
Damages or failure caused by acts of God, or resulting from improper consumer procedures, such as:
1. Improper maintenance
2. Misuse, abuse, abnormal use, or accident, and
3. Incorrect electrical voltage or current.
Removal or any alteration made on the FANTECH label control number or date of manufacture.
Any other warranty, expressed, implied or written, andtoany consequential or incidental damages, loss or
property,revenues, or profit, or costs of removal, installation or reinstallation, for anybreach of warranty.
WARRANTY VALIDATION
The user must keep a copy of the bill of sale to verify purchase date.
These warranties give you specific legal rights, and are subject to an applicable consumer
protection legislation. You may have additional rights which vary from state to state.
DISTRIBUTED BY:
a
d2
d1
b
c
ø D
FR Series performance is shown with ducted outlet. Per HVI’s Certified Ratings Program, charted air flow performance has been derated by a factor based on actual test results and the certified rate at .2 inches WG.
* Also available with 8" duct connection. Model FR 250-8. Special Order.
model
FR100
FR110
FR125
FR140
FR150
FR160
FR200
FR225
FR250
øD
9 1/2
9 1/2
9 1/2
11 3/4
11 3/4
11 3/4
13 1/4
13 1/4
13 1/4
d1
3 7/8
3 7/8
5 7/8
5 7/8
5 7/8
7 7/8
7 7/8
d2
4 7/8
4 7/8
4 7/8
6 1/4
6 1/4
6 1/4
9 7/8
9 7/8
9 7/8
a
6 1/8
6 1/8
6 1/8
5 7/8
5 7/8
6 3/8
6 1/4
6 1/4
6 1/4
b
7/8
7/8
7/8
1
1
1
1 1/2
1 1/2
c
7/8
7/8
7/8
7/8
7/8
1 1/2
1 1/2
1 1/2
All dimensions in inches
Fan
Model
Energy
Star
Rated
Watts
Wattage
Range
Max.
Amps
Max.
Ps
Duct
Dia.
RPM Volts
0" .2" .4" .6" .8" 1.0" 1.5"
FR100 2950 120 21.2 13 - 22 0.18 137 110 83 60 21 - - 0.90" 4"
FR125 2950 115 18 15 - 18 0.18 148 120 88 47 - - - 0.79" 5"
FR150 2750 120 71 54 - 72 0.67 263 230 198 167 136 106 17 1.58" 6"
FR160 - 2750 115 129 103 - 130 1.14 289 260 233 206 179 154 89 2.32" 6"
FR200 2750 115 122 106 - 128 1.11 408 360 308 259 213 173 72 2.14" 8"
FR225 3100 115 137 111 - 152 1.35 429 400 366 332 297 260 168 2.48" 8"
FR250*
- 2850 115 241 146 - 248 2.40 649 600 553 506 454 403 294 2.58" 10"
CFM vs. Static Pressure in Inches W.G.
United States 10048 Industrial Blvd. Lenexa, KS 66215 1.800.747.1762 www.fantech.net
Canada 50 Kanalflakt Way Bouctouche, NB E4S 3M5 1.800.565.3548 www.fantech.net
Fantech, reserves the right to modify, at any time and without notice, any or all of its products’ features, designs, co mpo nen ts and s pec ifi cat ion s to maintain their technological leadership position.
Item #: 411741
Rev Date: 021010
FR SERIES
THE ORIGINAL MITI GATOR
DIMEN SIONAL DATA
PERFO RMANCE DATA
NOTE:
Installations that will result in condensate forming in the outlet ducting should have a condensate bypass installed to route the condensate outside of the fan housing. Conditions that are likely to produce
condensate include but are not limited to: outdoor installations in cold climates, long lengths of outlet ducting, high moisture content in soil and thin wall or aluminum outlet ducting. Failure to install a proper con-
densate bypass may void any warranty claims.