Submittal Sheet
United States 10048 Industrial Blvd. • Lenexa, KS 66215 • 1.800.747.1762 • www.fantech.net
Canada 50 Kanalakt Way • Bouctouche, NB E4S 3M5 • 1.800.565.3548 • www.fantech.net
Systemair reserves the right to modify, at any time and without notice, any or all of its products’ features, designs, compo-
nents and specifications to maintain their technological leadership position.
Dimensions & Airflow
Dimensional information is in inches. Clearance of 14” (356mm) in front of the unit is recommended for removal
of core. All units feature three foot plug-in power cord with 3-prong plug.
Model A B C D E F
in mm in mm in mm in mm in mm in mm
FLEX 100H 21
1
/
2
546 14
1
/
2
368 15
5
/
8
397 17
7
/
8
454 22
1
/
2
572 15 381
fresh air
to inside
fresh air
from outside
stale air
from inside
stale air
to outside
Ventilation Performance
in. wg. (Pa) 0.1 (25) 0.2 (50) 0.3 (75) 0.4 (100) 0.5 (125) 0.6 (150) 0.7 (175) 0.8 (200)
cfm (L/s) cfm (L/s) cfm (L/s) cfm (L/s) cfm (L/s) cfm (L/s) cfm (L/s) cfm (L/s)
Net supply airow 130 (62) 122 (58) 113 (53) 104 (49) 95 (45) 86 (40) 76 (36) 65 (31)
Gross supply airow 135 (64) 127 (60) 118 (55) 108 (51) 99 (47) 89 (42) 79 (37) 68 (32)
Gross exhaust airow 134 (63) 122 (58) 112 (53) 102 (48) 93 (44) 84 (40) 75 (35) 63 (30)
Energy performance
Heating
Supply temperature Net airow Consumed power
Sensible recovery
efciency
Apparent sensible
effectiveness
1
Latent recovery/moisture
transfer
O
F
O
C cfm L/s W % % -
32 0 63 30 64 61 71 -
32 0 78 37 80 60 70 -
32 0 100 47 96 59 68 -
-13 -25 66 31 77 58 80 -
*Turbo Mode is an intermittent mode only. It can be activated with the RTS2, RTS5 and the ECO-Touch for up to 60 minutes.
Only the data of the normal speed are HVI certified.
** - Balancing Range : 70 cfm (33 L/s) to 110 cfm (52 L/s)
- If a balanced flow outside the above range is required, please revisit our product offerings to ensure a properly sized unit
is selected
0 25 50 75 100 125 150 175 200
0 12 24 35 47 59 71 82 94
0.0
0.2
0.4
0.6
0.8
1.0
0.0
50
100
150
200
250
Reduced Speed
Med Speed
Normal Speed
Turbo
4
3
2
1
1
4
3
2
Airow (L/s)
Airow (cfm)
Static Pressure (in H
2
O)
Static Pressure (Pa)
Distributed by:Contacts
Submitted by: Date:
Quantity: Model: Project #:
Comments:
Location:
Architect:
Engineer: Contractor:
Requirements and standards
• Complies with the UL 1812 requirements regulating the construction and installation of Heat Recovery Ventilators
• Complies with the CSA C22.2 no. 113 Standard applicable to ventilators
• Complies with the CSA F326 requirements regulating the installation of Heat Recovery Ventilators
• Technical data was obtained from published results of test relating to CSA C439 Standards
E
A
F
B
D
C
1
Not an HVI certied value


