Install Instructions
Dimensions in inches.
Diaphragm Correct
in all Positions
Correct Diaphragm
Positioning
Incorrect
Diaphragm
Positioning
Incorrect Diaphragm Positioning
Correct Diaphragm Positioning
Dimensional Data
Correct Switch
Positioning
- Diaphragm Positioned Vertically
Vertical Duct
Angled Duct
Horizontal Duct
Pr
essure Switch Positioning
Mount Fan
Mount Bracket
DBF4XL FAN/SWITCH INSTALLATION INSTRUCTIONS
Fan Installation
Step 1. Selecting Fan Location
Fan must be mounted a minimum of 5 linear feet from the dryer outlet. In order to perform recom-
mended maintenance, fan location should allow sufficient access for service. Refer to dimensional draw-
ings shown below.
Step 2. Mount Bracket
Using the wood screws provided, attach the mounting bracket to a support beam at the selected loca-
tion. Fan mounting can be in any angle, however, vertical mounting is recommended to reduce conden-
sation buildup in the fan. If a horizontal installation is necessary and condensation buildup may pose a
problem, a 1/4" hole drilled in the bottom of the housing (along with an NPT insert and drain tubing) may
be installed to allow condensation to drain.
Step 3. Mount Fan
For proper operation, the switch diaphragm should be positioned vertically.
(Illustrations below show
diaphragm position for horizontal, vertical and ducts installed at an angle.) Wiring box should be posi-
tioned for easy access. Attach fan to the mounting bracket with the self tapping screws provided. Care
should be taken not to strip the housing. Although screw pilot holes are not required, 3/32" (or smaller)
pilot holes are recommended.
NOTE: Steps 2 & 3 may be reversed.