DBF 110 Specification Sheet

Fantech DBF110 Series Dryer Booster System
Description
A integral centrifugal fan and positive pressure sensing switch specically designed for residential dryer vent
booster applications. The fan can be mounted in any angle at any point along the duct work and straight-through
air ow design allows easy installation. By using FC type mounting clamps, fan can easily be removed from duct
work for service. Fan inlet and outlet are 3 7/8” diameter allowing direct installation into dryer vent duct thereby
eliminating the need for transition pieces. Motor bearings are a permanently sealed, self lubricating ball type.
DBF110 fan is backed by Fantech’s Five Year Warranty.
Installation Notes:
1) For maximum sensitivity, switch diaphragm must be mounted vertically. Failure to orient the
diaphragm vertically may result in improper operation.
2) Fan must be mounted a minimum of 15 linear (not equivalent) feet from the dryer in order to
prevent the impeller from loading with wet lint. If mounted within 15 feet, a secondary lint trap
(DBLT4) must be used. (see installation manual)
3) Fan should be inspected periodically, depending on amount of usage, and cleaned as necessary.
Guide Specications for Model DBF110 Dryer Vent Booster System
Inline fan shall be of the centrifugal, direct driven type.
Construction
Housing
Fan housing shall be constructed of UV resistant ABS-PC blen thermophastic.
Fan shall be supplied with an integreal external electrical terminal box with pre-wired terminal strip
connections.
Capacitor shall be provided and shall be located within the fan electrical terminal box.
Motor
Motorized impeller shall be an external rotor type, class B insulation, totally enclosed permanent split
capacitor type.
Bearings shall be permanently sealed self lubricating ball type
Motor shall be equipped with automatic reset thermal overload protection.
Motors shall be acceptable for continuous duty.
Wheel
Fan wheel shall be of the backward inclined centrifugal type with an inlet venturi for maximum performance.
Motorized impeller shall be both statically and dynamically balanced as one integral unit to provide for
vibration free performance.
Switch
Integral positive pressure switch shall be mounted on the fan and prewired to the terminal strip
provided in fan electrical junction box.
Switch shall be set to 0.05” H
2
O
g
static pressure.
Switch shall incorporate a delay-on-break timer cycle to maintain fan performance for intervals of
10 minutes until drying cycle is complete.
Code Approval
Fan shall be tested and approved by UL and CSA (or equals) for safety.
Rating shall include approval for residential dryer exhaust and air stream temperatures not to exceed
140˚F (60˚C).
K EC Series shall be manufactured under the authority of Fantech, Inc., Lenexa, KS.
Article #: 450426
Rev Date: 081412
United States 10048 Industrial Blvd. · Lenexa, KS 66215 · 800.747.1762 · www.fantech.net
Canada 50 Kanalakt Way · Bouctouche, NB E4S 3M5 · 877.797.2471 · www.fantech.net
Fantech, reserves the right to modify, at any time and without notice, any or all of its products’ features, designs, components and specications to maintain their
technological leadership position.

Summary of content (1 pages)