Introduction
Specification
Installation
Filtration Stage 1 & 2 Pre-Filter with Carbon (#463046)
Filtration Stage 3 HEPA Filter (# 463048)
Weight 28 lbs (12.7 kg)
Plenum Mount Port Opening 16" x 3.5" (406 mm x 89 mm)
Collar Mount Port Opening 8" (203 mm) Round*
Installtion Type Plenum, Wall* or Floor* Mounted
Electrical Supply 120VAC @ 60 Hz
Power Consumption 134W
Certication cCSAus
Airow (low/high speed) 220/300 cfm
RETURN AIR PLENUM INSTALLATION
Front View Side View - Clearance Back View
17"
(431mm)
12"
(307mm)
12"
(305mm)
17"
(431 mm)
22"
(557mm)
RETURN AIR PLENUM INSTALLATION AND STAND ALONE INSTALLATIONS
Front View Side View - Clearance Side View
17"
(431mm)
12"
(307mm)
12"
(305mm)
13"
(328mm)
22"
(557mm)
8"
(201 mm)
Power connection
HEPA AIR FILTRATION SYSTEMS
You have purchased a very effective air cleaning and treatment system
incorporating HEPA (High Efciency Particulate Arrestance) lter
technology. This is the type of air cleaning equipment that respiratory
specialists recommend most.
To optimize the performance of your HEPA Filtration System, it should
be installed by a professional contractor who is familiar with your indoor
air quality situation and the operation of other heating, ventilation and air
conditioning equipment that you may have.