BUZZER A warning buzzer sounds when any one of the power supplies
fails. The warning buzzer is reset table from reset switch either
the one in front control panel or the one on the rear side.
LEDS The warning LEDS can be found either on the rear side or the
control panel of the power system. Tells if one of the two power
supplies has failed, by LED blinking.
HOT-PLUGGABLE The power system provides a Hot-Pluggable function
This method allows the power units in the Disk Array/
File Server to be removed or inserted very easily without
9.HOT-SWAP PROCEDURES
Please refer to the followings when either one power supply unit is fount defective.
A) Locate the defective power supply by examining the individual LED on the
power unit or the LED on the front control panel if LED is Blinking.
B) Unlock & Remove the defective power supply unit.
C) Replace a new GOOD power supply unit, Insert the power supply into the
power system chassis in position & it will auto Lock-up.
D) Turn on the new power supply unit.
E) Check the module LED which indicate the power and LED of total power
system status, Both LED shall Have steady life.
10.PINOUTS OF CONNECTORS
7x 5.25, 1 x 3.5, 1 x ATX-24Pin or 20Pin(for motherboard), 1 x 8Pin Power Connector
1 x +12V Power Connector
Color Reference for LED cable
POWERѮ 1 LED Cable Brown / with
POWERѮ 2 LED Cable Red / with
MAIN POWER LED Cable Green / with