Datasheet

6.4. Short circuit protection
Output Comments
+3.3V PSU shutdown
+5V PSU shutdown
+12V PSU shutdown
NoteThe Short circuit protection should be tested at other load rating.
6.5. Thermal Protection
The power supply shall go into thermal protection as the case temperature exceeds 86 (±5℃)
limit. The output shall recover only when the temperature becomes normal and
AC power is turned
on again.
7. Power System Signal status
7.1. Buzzer status
Power Supply Condition Buzzer status
No AC power to all PSU OFF
AC present/Only Standby Output On OFF
Power supply DC outputs ON and OK OFF
Power supply failure Beeping
7.2. LED indicators
Power Supply Condition
Power system status
Per Power Module status
LED Color RED GREEN ORANGE
No AC power to all PSU OFF OFF OFF
AC present/Only Standby Output On ON OFF OFF
Power supply DC outputs ON and OK OFF ON ON
Power supply failure
OFF
Blinking
OFF
SURE STAR
SURE STAR