How to Wire and Operate Your Wall Control
Figure 2
Figure 1
WC3WH Wall Control
DESCRIPTION: Single 3-speed ceiling fan control with light up/down dimmer switch
ELECTRICAL SPECS: 120V, 60Hz Ceiling Fan
FAN MODELS USED: most Fanimation fans - see catalog or visit our website, fanimation.com
for more information
SPECIFICATION and INSTRUCTION SHEET
NOTE: Supply wires and fan wires
omitted for clarity.
1. Connect wires using connectors as shown in Figure 1.
WARNING
To avoid possible electrical shock, be sure electricity is
turned off at the main fuse box before wiring.
NOTE: If fan or supply wires are different colors than indicated, have this unit installed by a qualified electrician.
Make wire connections and secure with wire nuts
supplied.
Attach wall control unit to outlet box using the two
screws provided. Then, attach face plate to the wall
control. (Figure 2)
2.
• Restore electrical power.
3. Operating Wall Control: (Figure 3)
- Fan off
- Up Light: Turns light ON/OFF.
- Fan speed control: Turns on fan and turns speed
up or down.
- Light Dimmer: Up or down to brighten or dim
light.
- Indicator LED light
- Pull out to turn all power off.
- Down Light: Turns light ON/OFF.
• Connect the Black wire from the wall-mounted
control with the wire from the wire of A. C. power
supply.
• Connect the Black wire from the wall-mounted
control with the Black wire from the ceiling fan.
• Connect the Blue wire from the wall-mounted
control with the Blue wire from the ceiling fan.
• Connect the Orange wire from the wall-mounted
control with the Orange wire from the ceiling fan
• Connect the green/yellow wire from the ceiling fan
with the ground wire.
Figure 3
YELLOW & GREEN
BLUE
BLACK
GROUND
TO MOTOR L
FOR LIGHT DOWN
YELLOW & GREEN
BLUE
BLACK
ORANGE
FOR LIGHT UP
ORANGE
BLACK
AC IN L
AC IN N
Face Plate
Screw
Outlet Box
WARNING
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not operate
fan unless blades are in place. Noise and fan damage
could result.
To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box and
not pinched between the wall plate and the wall.
WARNING