Datasheet
PC/ABS Alloy, PA 66 GF13 HSL for elastic
clips
Type of material:
RAL 7035 - other colors on request
Standard color:
IP54, according to 60529 standard
Type 12 according to UL 508 Std
Protection degree:
by elastic clips, otherwise by four
self-threading screws
Fixing system:
from 1 mm to 2.1 mm
Plate thickness:
from -45°C to +75°C
Storage temperature:
100,000 h
Lifetime L10 at 25°C:
thermally
Motor protection:
by terminal block 2 poles L-N
Electrical connection:
(by M4 screw on fan's casing)
Earth connection:
class l
Appliance class:
thermo-linked progressive structure synthetic
fibre
Type of filter media:
class G3, according to EN 779
Filtering class:
85% - DIN 24185
Degree of separation:
600 g/m^2
Dust retention capacity:
filter media is washable for about 10 times
Note:
0.8 Kg
Weight:
CE, UL E223195 / UL E237844
Approvals:
"FF12AN" SERIES FAN FILTERS
Description:
Fan Filter 115/230 Va.c.
technical drawing
mounting cut-out
(W)
Approvals
Rated
Temp. Range
Noise
Static
Pressure
Rated
Power
Max
Air Flow**
Rated
Current
FrequencyVoltageModel
(A)(V) (Hz) (°C)[db(A)](Pa)(m3/h)
FF12A115UN
115 V a.c. 60
0.220
67/79 73/86 43.0/48.0 -10 ÷ +5517 CE; cURus
FF12A115UNR
115 V a.c. 60
0.220
60/70 86/111 43.0/48.0 -10 ÷ +5517 CE; cURus
FF12A230UN
230 V a.c. 50/60
0.130/0.100
67/79 73/86 43.0/48.0 -10 ÷ +5518/16 CE; cURus
FF12A230UNR
230 V a.c. 50/60
0.130/0.100
60/70 86/111 43.0/48.0 -10 ÷ +5518/16 CE; cURus
data with uncertainty of 15%
All specifications, data and drawing are subject to change without notice and are approximate. Please refer to our terms of sales including our warranty and limited liabilities clauses.