Owners Guide
14
OPERATION
WHEN TO TURN ON THE HOOD?
Switch on the hood at least one minute before starting to cook to direct
fumes and vapours towards the suction surface.
After cooking, leave the hood operating until complete extraction of all
vapours and odours. By means of the Timer function, it is possible to set
auto switch-o function which will allow the hood to turn o automat-
ically after 15 minutes of operation.
WHICH SPEED IS TO BE SELECTED?
1st speed: maintains the circulation of clean air with low electricity
consumption.
2nd speed: normal conditions of use.
3rd speed: presence of strong odours and vapours.
4th speed: rapid disposal of odours and vapours.
WHEN SHOULD THE FILTERS BE WASHED OR REPLACED?
The metal lters must be cleaned every 30 hours of operation.
The active carbon lters must be replaced every 3-4 months, depend-
ing on the use of the hood.
For further details refer to the “MAINTENANCE” section.
USE OF MECHANICAL PUSH BUTTON CONTROL PANEL
(VULCANO 24" - FPVUL24W3SS)
OFF 1 2 3
Light on/o
OFF
OFF button
Press this button to switch the motor o
1
Button 1: Press this button (button in) to start or set
the motor at minimum speed
2
Button 2: Press this button (button in) to start
or set the motor at medium speed
3
Button 3: Press this button (button in) to start or
set the motor at maximum speed
ELECTRONIC PUSHBUTTON PANEL
Motor ON/OFF
Upon start-up, the speed is that stored at the previous op-
eration.
Increase speed
from 1 to 4
Speed 4 is only active for a
few minutes, then speed 3
activates.
The speeds are indicated by
the LEDs on the keys:
Speed 1
Speed 2
Speed 3
Speed 4
("+" LED ashing)
Reduce speed
from 4 to 1
Light on/o
TIMER (red LED ashing)
Auto switch-o after 15 min.
The function deactivates (red LED o) if:
- The TIMER key ( ) is pressed again.
- The ON/OFF key ( ) is pressed.
FILTER ALARM (red LED steady on with ( ) o)
Anti-grease lter maintenance after approximately 30 hours
of operation.
Press ( ) the meter for 3 seconds to reset.
600
cfm
600
cfm
280
cfm