Brochure

Fig. 13 - Incorrect Connecons
A
B
C
D
E
F
G
Never connect two acve components (snap hooks or carabiners)
to each other.
Never connect two acve components (snap hooks or carabiners)
to a single D-ring at the same me.
Never connect in a way that would produce a condion of loading
on the gate.
Never aach to a object in a manner whereby the gate (of the snap
hook or carabiner) would be prevented from fully closing and locking.
Always guard against false connecons by visually inspecng for closure
and lock.
Never aach explicitly to a constuent subcomponent (webbing,
cable or rope) unless specically provided for by the manufacturer’s
instrucons for both subcomponents (snap hook or carabiner and
webbing, cable or rope).
Never aach in a manner where an element of the connector (gate or
release lever) may become caught on the anchor thereby producing
addional risk of false engagement.
Never aach a spreader snap hook to two side/posioning D-rings
in a manner whereby the D-rings will engage the gates; the gates
on a spreader must always be facing away from the D-rings during
work posioning.
Acronyms for Fall Protecon and Fall Arrest; ANSI Z359.0-2012
INSPECTION RECORD PLANILLA de INSPECCIÓN
Siglas para la protección y detención de caídas; ANSI Z359.0-2012
Other Acronyms for Fall Protecon and Fall Arrest
Other Acronyms for Fall Protecon and Fall Arrest
ACTD
Model # Modelo N° :____________________
Date of Manufacture Fecha de fabricación :____________________
Serial # N° de serie :____________________
ACTD
RGLS
RGLS
HLL HLL
ANSI
ANSI
DDV
DDV
RPA
RPA
PPE
PPE
TPA
TPA
AD AD
SAL
SAL
MAF MAF
OSHA
OSHA
FACSS
FACSS
SRD
SRD
CSS CSS
cm
cm
mm mm
ASTM
ASTM
FAS
FAS
TFD
TFD
FF
FF
VLLSS
VLLSS
DD
Inspecon Date
Fecha de inspección
Inspector
Inspector
Comments
Observaciones
Pass/Fail
Pasó/No pasó
Correcve Acon Needed
Accion correcva a realizer
Approved By
Aprobado por
DD
kN
kN
PFAS
PFAS
lbs
lbs
FBH
FBH
VLL
VLL
FFD
FFD
WPS
WPS
Acvaon Distance Distancia de acvación
Rope Grab Lanyard Set
Equipo de agarre de cordón/cuerda
Horizontal Lifeline Cuerda de salvamento horizontal
American Naonal Standards
Instute
Instuto Nacional de Normas
de los Estados Unidos
Deceleraon Device
Disposivo de desaceleración
Rebar Posioning Assembly
Ensamblaje de posicionamiento
con refuerzo
Personal Protecve Equipment
Personal Protecve Equipment
Tower Posioning Assembly
Ensamblaje de posicionamiento
con torre
Arrest Distance Distancia de detención
Shock Absorbing Lanyard
Cuerda de salvamento
con amorguación
Maximum Arrest Force Fuerza de detención máxima
Occupaonal Safety and Health
Administraon
Administración de Seguridad y
Salud Ocupacional
Fall Arrestor Connecng Subsystem
Subsistema de conexión de
detenedor de caídas
Self-retracng Device
Self-retracng Device
Connecng Subsystem Subsistema de conexión
Cenmeters
Cenmetros
Millimeter Milímetro
American Society for Tesng
and Materials
Sociedad Americana de Pruebas
y Materiales
Fall Arrest System
Sistema de detención de caídas
Total Fall Distance
Total Fall Distance
Free Fall
Caída libre
Vercal Lifeline Subsystem
Vercal Lifeline Subsystem
Deceleraon Distance Distancia de desaceleración
kilo-Newton
Kilo Newton
Personal Fall Arrest System Sistema personal de detención
de caídas
pounds (weight)
Libras (peso)
Full Body Harness
Arnés de cuerpo completo
Vercal Lifeline
Vercal Lifeline
Free Fall Distance
Distancia de caída libre
Work Posioning System
Work Posioning System
Fig. 13 - Conexiones incorrectas
A
B
C
D
E
F
G
Nunca conecte dos componentes acvos (ganchos de cierre instantáneo
o mosquetones) entre sí.
Nunca conecte dos componentes acvos (ganchos de cierre instantáneo
o mosquetones) a un solo anillo en “D” al mismo empo.
Nunca se debe conectar de una manera que se produzca una condición
de carga en la hebilla.
Nunca conecte a un objeto de tal manera que
la hebilla (del gancho de cierre instantáneo o del mosquetón) se vea
impedida de cerrarse y bloquearse por completo. Siempre protéjase de
falsas conexiones mediante la inspección visual del cierre y bloqueo.
Nunca conecte explícitamente a un subcomponente constuyente
(correa, cable o cuerda), a menos que se hayan proporcionado
especícamente por las instrucciones del fabricante para los
subcomponentes (gancho de cierre instantáneo o mosquetón y correa,
cable o cuerda).
Nunca conecte de modo que un elemento del conector (hebilla o
palanca de liberación) pueda quedar atrapada en el anclaje y por lo
tanto producir un riesgo adicional de conexión falsa.
Nunca conecte un gancho de cierre instantáneo del esparcidor a dos
anillos en “D” laterales/de posicionamiento en una forma que los
anillos en “D” se acoplen a la hebillas; las hebillas en un esparcidor
deben estar siempre orientadas hacia el lado opuesto de los anillos en
“D” durante el posicionamiento del trabajo.
TUCON.2
DUCON.2
TUAA.2
Incorrect Connections / Acronyms for Fall Protection and Fall Arrest / Inspection Record
APPENDIX B
03122014
28