Operation Manual

37
Programming the vehicle’s functions
EN
X
Press the “Programmieren” key of the charging unit.
X
Programme the values you want the CVs to have. You will find the
standard values and ranges to be complied with in Table 2 “Configu-
ration Variables”.
CV Description Value Range
»1« Digital address 3 1-127
»2« Minimum speed 1 1-63
»3« Time lag on starting 5 1-63
»4« Time lag on braking 10 1-63
»5« Maximum speed 63 1-63
»6« Average speed 25 1-63
»7« Version
»17« Long address High Byte 199 0-255
»18« Long address Low Byte 208 0-255
»20« Normal speed 50 0-255
»21« Slow speed 25 0-255
»23« Light PWM lighting Rear lights 8 0-32
»24« Waiting time A on switching the ope-
rating voltage on - in 0.5 s steps
6 0-255
»25« Waiting time B after motor standstill
up to stop lights off - in 0.5 s steps
6 0-255
»26« Waiting time C after motor standstill
up to headlights off - in 0.5 s steps
20 0-255
»27« Waiting time D up to motor start via
magnetic switch - in 0.5 s steps
1 0-255
»28« Light PWM lighting Headlights 8 0-32
»29« DCC Configuration
Bit 0 = Inverting the motor’s direction
of rotation
Bit 1 = 1 = 28 driving speeds
Bit 5 = 1 long address
6 0-255