User manual

GB
Art. No. 140344 »Super-Wave-Swinger« Roundabout
CAUTION! You will reprogram the control unit at your own risk.
Wrong reprogramming of the control unit may damage the model!
Function
---------------
Start contact:
------------------------
Starts the sequence. If contact is permanently closed, the sequence will be triggered again after a pause (CV75).
Digital operation:
-------------------------------
Whenever a points command that is valid for the decoder is received, the red LED flashes briefly.
Digital mode 1: (CV49-Bit0=0)
A digital points command »green« corresponds to the start contact and starts the sequence. The corresponding points command »red« will be ignored.
Digital mode 2: (CV49-Bit0=1)
A digital points signal »green« starts the sequence on continuous operation
A digital points signal »red« switches continuous operation off at the end of the current ride.
Sequence:
------------------
Whenever the control is connected to the operating voltage, Motor 2 first moves downwards to its final position until Switch S1 is closed.
If start key is actuated, this starts the sequence consisting of 10 steps.
Step 0:
Motor 2 is started. Speed and start delay are set using CV51 and CV53 respectively.
The duration of that step is set in 0.5 s steps using CV53.
Step 1:
Motor 2 is stopped.
Motor 1 is started. Speed and start delay are set using CV54 and CV55 respectively.
The duration of that step is set in 0.5 s steps using CV56.
Step 2:
Motor 2 runs upwards. Speed and start delay of Motor 1 and Motor 2 respectively can be set using CVs 57, 58, 59, 60.
Step 2 terminates when upper Switch S2 is closed.
Step 3:
Motor 1 runs. Running time can be set in 0.5 s steps using CV61.
Step 4:
Motor 2 runs downwards. Speed and start delay of Motor 1 and Motor 2 respectively can be set using CVs 62, 63, 64, 65.
Step 4 terminates when lower Switch S1 is closed or when the running time of Step 4 set in CV66 (in 0.5 s steps) is reached.
Step 5:
Motor 1 runs. Running time can be set in 0.5 s steps using CV67.
Step 6:
Motor 2 runs upwards. Speed and delay of Motor 1 and Motor 2 respectively can be set using CVs 68, 69, 70, 71.
Step 6 terminates when upper Switch S2 is closed.
Step 7:
Motor 1 runs. Running time can be set in 0.5 s steps using CV72.
Step 8:
Motor 2 runs downwards. Speed and delay of Motor 1 and Motor 2 respectively can be set using CVs 73, 74, 75, 76.
Step 8 terminates when lower Switch S1 is closed.
Step 9:
Motor 1 is given desired speed 0 and brakes, braking delay can be set using CV77. That step terminates when motor speed is 0.
Step 10:
If start switch is closed, the sequence will be started again after a time lag that can be adjusted in CV78, otherwise the sequence terminates.