Door Thickness:
1-
3
/
8 to 1-
3
/
4 standard.
Backset:
2-
3
/
4 standard; 2-
3
/
8 also available.
Mechanism:
Parts constructed of brass or cold-formed steel, zinc plated and dichromated for rust
resistance. Springs are stainless steel.
Attachment:
Lock chassis secured to door by two screws which pass through a steel rose insert
inside and thread directly into the outer rose-mounting assembly, and two screws that screw into
the chassis assembly.
Handing:
Locks are non-handed.
Cylinder:
Pinning in six chambers. Cylinder assemblies removable to re-key. Also available with
6- or 7-pin interchangeable core cylinders. Cylinder housings and plugs machined from solid brass.
Springs are stainless steel. Two nickel silver keys furnished standard.
Competitor Cylinder:
The W Series accepts standard 6-pin cylinders available from Falcon, as
well as Schlage, Corbin-Russwin, Yale and Sargent.
Keyways:
“G” keyway standard on Falcon standard cylinders. “A” keyway standard on I/C core
cylinders. Also available with some optional keyways. Schlage “C” keyway also available on
standard cylinders, includes master key. Master keying available on all Falcon and Schlage
“C” keyways.
Trim:
Roses are heavy wrought brass or bronze, installed over steel rose inserts which are through-
bolted through door. Levers are pressure-cast zinc (solid levers-no-inserts) fi nished
to match mating parts.
Latches:
1
/
2 bolt projection made of stainless steel and UL listed for 3-hour door assemblies.
Latches have self-adjusting fronts to accommodate beveled or fl at doors. 2-
3
/
8 backset with
1” x 2-
1
/
4 latch faces or 2-
3
/
4 backset with 1-
1
/
8 x 2-
1
/
4 latch faces.
Strikes:
4-
7
/
8 x 1-
1
/
4 ANSI strike with curved lip to meet ANSI A115.2 door frame preparation
standard. Consult Options and Accessories section for other available strikes, sizes and
confi gurations.
Screws:
Furnished with combination screws for use in wood or metal doors and frames.
ANSI/BHMA:
Meets ANSI/BHMA A156.2, Series 4000, Grade 2.
UL: