User Manual
44
13. Technical Data
This cooker is designed for use on Natural gas, although a conversion for LP (LPG X Propane (2.54 kPa)) gas is included.
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION: Australia.
Pressures
Gas (Rp ½ at rear right-hand side) Electric
Supply Pressure
at the inlet to appliance regulator
230/400 V 50 Hz
Natural Gas 1.13 kPa
Propane 2.75 kPa
Operating Pressure
at appliance test point
Natural Gas 1 kPa
Propane 2.54 kPa
Dimensions
Model PROFESSIONAL + 100 FX Dual Fuel
Overall height minimum 905 mm maximum 930
mm
Overall width 994 mm
Overall depth
604 mm excluding handles, 642 mm including handles
Minimum height above the hotplate
650 mm
Ratings
Hotplate
Bypass
Screw*
Natural Gas 1.0 kPa Propane 2.54 kPa
Input
Injector
Input
Injector
Marking Size Ø Marking Size Ø
Wok burner 55 15.2 MJh
-1
internal 88 0.88 mm
15.0 MJh
-1
internal 57 0.57 mm
external 168 1.68 mm external 98 0.98 mm
Large burner 41 12.3 MJh
-1
165 1.65 mm 12.0 MJh
-1
89 0.96 mm
Medium burner 33 6.2 MJh
-1
115 1.15 mm 6.2 MJh
-1
67 0.68 mm
Small burner 25 3.7 MJh
-1
92 0.92 mm 3.3 MJh
-1
48 0.50 mm
Gas burner inputs based on Gross Caloric Value.
* The valves in this cooker are tted with adjustable bypass screws. The cooker is supplied with the bypass screws set for Natural Gas. For LPG conversion the
bypass screws must be screwed all the way down.
Oven Efficiencies
Ovens
Left-hand Oven Right-hand Oven
Multi-function Multi-function
Maximum power output @ 230 V 50 Hz
2.5 kW 2.5 kW
Energy eciency class on a scale of A (more ecient) to G (less ecient) A A
Energy consumption based on standard load
0.88 kWh 0.75 kWh
Usable volume (litres) 80 55
Size Large Medium
Time to cook standard load
41 minutes 44 minutes
Surface area of the grid
1400 cm
2
1056 cm
2
Maximum power output @ 230 V 50 Hz - Right-hand oven, multi-function with duo (tall oven) 3.42 kW
Maximum total electrical load at 230 V (approximate total including oven lights, oven fan, etc.): 5.9 kW
†
.
†
Arithmetic mean value when measured under full load stabalised conditions, Clause 10 AS NZS 60335.