Operation Manual

57
English
Technical Data
This cooker is category II2H3+
It is supplied set for group H natural gas. A conversion kit from NG to LP gas is packed with the cooker.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION : Cooker back, serial number repeater badge below oven door opening.
Country of Destination: GB/IE
Gas Electric
Natural Gas 20mbar 220 - 240V 50Hz
Butane 29mbar
Propane 37mbar
(See appliance data badge for test pressures)
Dimensions
Overall height
minimum 896mm maximum 925mm
Overall width
1100mm See ‘Positioning of Cooker
Overall depth
648mm
Space for fixing
See ‘Positioning of Cooker’
Minimum space above hotplate
650mm
Connections
Gas: Electric
Rp 1/2 at rear right-hand side 220 - 240V 50Hz
Ratings
Natural Gas L.P. Gas
Hotplate
Injector Injector
Right hand Wok burner
3.65kW
internal 80
3.5kW (255g/h)
internal 54
external 129 external 77
Large Burners
3.0kW 134 3.0kW (218g/h) 87
Medium Burners
1.7kW 109 1.7kW (124g/h) 68
Small Burner
1.0kW 75 1.0kW (73g/h) 51
Gas burner inputs based on Gross Calorifi c Value
Ceramic Hob
Front element 1.1kW
Rear element 1.1kW
Ovens
Multifunction Forced air convection
Energy effi ciency class :
on a scale of A (more effi cient) to G (less effi cient) B A
Energy consumption based on standard load 0.90kWh 0.85kWh
Usable volume (litres) 62 67
Size Medium Large
Time to cook standard load 41 minutes 38 minutes
Baking area 1400cm2 1400cm2
Grill
2.3kW
Slow cook oven
1 kW
Maximum total electrical load at 230V 11.7kW (approximate total including oven lights, oven fan etc.)