User Manual
41
12. Technical Data
This cooker is designed for use on Natural Gas, although a conversion for LP (LPG X Propane (2.54 kPa)) gas is packed with the
cooker.
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION: Australia.
Connections
Gas (Rp ½ at rear right-hand side) Electric
Natural gas
1 kPa
230 V 50 Hz
Propane 2.54 kPa
See the appliance badge for test pressures.
Dimensions
Overall height minimum 905 mm maximum 930 mm
Overall width 1092 mm
Overall depth 608 mm excluding handles; 670 mm including handles
Minimum space above the hotplate 650 mm
Refer to 'Positioning the Cooker'.
Ratings
Hotplate Bypass Screw*
Natural Gas 1 kPa LP Gas 2.54 kPa
Input Injector Input Injector
Wok burner 55
15.2 MJh
Internal 88
15.0 MJh
Internal 57
External 168 External 98
Large burner 41
12.3 MJh 165 12.0 MJh 89
Medium burner 33
6.2 MJh 115 6.2 MJh 67
Small burner 25
3.7 MJh 92 3.3 MJh 48
* The valves in this cooker are fitted with adjustable bypass screws. The cooker is supplied with the bypass screws set for
Natural gas. For LPG conversion the bypass screws must be screwed all the way down.
Oven Efficiency
Ovens
Left-hand Oven Right-hand Oven
Forced Air
Convection
Forced Air
Convection
Maximum power output @ 230 V 50 Hz 2.5 kW 2.5 kW
Energy eciency class on a scale of A (more ecient) to G (less ecient) A A
Energy consumption based on standard load
0.90 kWh 0.90 kWh
Usable volume (litres) 69 69
Size Large Large
Time to cook standard load 38 minutes 38 minutes
Surface area of the grid
1400 cm
2
1400 cm
2
Grill 2.3 kW
Warmer 160 W
Maximum total electrical load at 230 V (approximate total including oven lights, oven fan, etc.): 7.43 kW.