Datasheet

3 www.fairchildsemi.com
NC7S02
AC Electrical Characteristics
Note 3: C
PD
is defined as the value of the internal equivalent capacitance which is derived from dynamic operating current consumption (I
CCD
) at no output
loading and operating at 50% duty cycle. (See Figure 2.) C
PD
is related to I
CCD
dynamic operating current by the expression:
I
CCD
= (C
PD
)(V
CC
)(f
IN
) + (I
CC
static).
AC Loading and Waveforms
C
L
includes load and stray capacitance
Input PRR = 1.0 MHz; t
w
= 500 ns
FIGURE 1. AC Test Circuit
Input = AC Waveform;
PRR = variable; Duty Cycle = 50%
FIGURE 2. I
CCD
Test Circuit
FIGURE 3. AC Waveforms
Symbol Parameter
V
CC
T
A
= +25°CT
A
= 40°C to +85°C
Units Conditions
Figure
Number
(V) Min Typ Max Min Max
t
PLH
, Propagation Delay 5.0 3.5 15 ns C
L
= 15 pF
Figures
1, 3
t
PHL
2.0 19 100 125
C
L
= 50 pF
3.0 10.5 27 35
ns
4.5 7.5 20 25
6.0 6.5 17 21
t
TLH
, Output Transition Time 5.0 3 10 ns C
L
= 15 pF
Figures
1, 3
t
THL
2.0 25 125 155
C
L
= 50 pF
3.0 16 35 45
ns
4.5 11 25 31
6.0 9 21 26
C
IN
Input Capacitance Open 2 10 10 pF
C
PD
Power Dissipation Capacitance 5.0 6 pF (Note 3) Figure 2