Datasheet
FSA2267/FSA2267A 0.35 Low-Voltage Dual-SPDT Analog Switch
© 2005 Fairchild Semiconductor Corporation www.fairchildsemi.com
FSA2267 / FSA2267ARev. 1.0.5 3
Absolute Maximum Ratings
Stresses exceeding the absolute maximum ratings may damage the device. The device may not function or be opera-
ble above the recommended operating conditions and stressing the parts to these levels is not recommended. In addi-
tion, extended exposure to stresses above the recommended operating conditions may affect device reliability. The
absolute maximum ratings are stress ratings only..
Notes:
1. The input and output negative voltage ratings may be exceeded if the input and output diode current ratings are
observed.
2. Minimums define the acceptable range of current. Negative current should not exceed minimun negative values.
Recommended Operating Conditions
The Recommended Operating Conditions table defines the conditions for actual device operation. Recommended
operating conditions are specified to ensure optimal performance to the datasheet specifications. Fairchild does not
recommend exceeding them or designing to absolute maximum ratings.
Note:
3. Unused inputs must be held HIGH or LOW. They may not float.
Symbol Parameter Min. Max. Unit
V
CC
Supply Voltage -0.5 +5.5 V
V
S
Switch Voltage
(1)
-0.5 V
CC
+ 0.5 V
V
IN
Control Input Voltage
(1)
-0.5 5.5 V
I
IK
Input Diode Current
(2)
-50 mA
I
SW
Switch Current 350 mA
I
SWPEAK
Peak Switch Current
(Pulsed at 1ms Duration, <10% Duty Cycle)
500 mA
T
STG
Storage Temperature Range -65 +150 °C
T
J
Maximum Junction Temperature +150 °C
T
L
Lead Temperature (Soldering, 10 Seconds) +260 °C
ESD
Human Body Model: FSA2267 7500 V
Human Body Model, JESD22-A114:FSA2267A 7000 V
Charged Device Model, JESD22-C101:
FSA2267/FSA2267A
1000 V
Symbol Parameter Min. Max. Unit
V
CC
Supply Voltage V
FSA2267 1.65 3.6 V
FSA2267A 2.3 4.3
V
IN
Control Input Voltage
(3)
0V
CC
V
V
SW
Switch Input Voltage 0 V
CC
V
T
A
Operating Temperature -40 +85 °C