Datasheet

8 www.fairchildsemi.com
FPF2000-FPF2007 Rev. H
FPF2000-FPF2007 IntelliMAX™ Advanced Load Management Products
Typical Characteristics
Figure 19. Short Circuit Response Time Figure 20. Current Limit Response
(Output Shorted to GND) (Switch power up to hard short)
Figure 21. Current Limit Response Time
Note 3: V
DRV
signal forces the device to go into overcurrent condition.
V
IN
2V / DIV
I
OUT
2A/DIV
V
OUT
2V/DIV
20µS/DIV
20µS/DIV
V
IN
/V
ON
2V/DIV
I
OUT
200mA/DIV
V
IN
= V
ON
C
IN
= 10µF
C
OUT
= 1µF
Active High Devices
C
IN
= 10µF
C
OUT
= 1µF
Active High Devices
V
IN
2V/DIV
V
ON
2V/DIV
I
OUT
100mA/DIV
V
OUT
(SHORTED
TO GND)
20µS/DIV
C
IN
= 10µF
C
OUT
= 1µF
Active High Devices