Datasheet

FNC42060F / FNC42060F2 Motion SPM® 45 Series
©2013 Fairchild Semiconductor Corporation 11 www.fairchildsemi.com
FNC42060F / FNC42060F2 Rev. C3
Time Charts of Protective Function
a1 : Control supply voltage rises: after the voltage rises UV
CCR
, the circuits start to operate when next input is applied.
a2 : Normal operation: IGBT ON and carrying current.
a3 : Under-voltage detection (UV
CCD
).
a4 : IGBT OFF in spite of control input condition.
a5 : Fault output operation starts.
a6 : Under-voltage reset (UV
CCR
).
a7 : Normal operation: IGBT ON and carrying current.
Figure 11. Under-Voltage Protection (Low-Side)
b1 : Control supply voltage rises: after the voltage reaches UV
BSR
, the circuits start to operate when next input is applied.
b2 : Normal operation: IGBT ON and carrying current.
b3 : Under-voltage detection (UV
BSD
).
b4 : IGBT OFF in spite of control input condition, but there is no fault output signal.
b5 : Under-voltage reset (UV
BSR
).
b6 : Normal operation: IGBT ON and carrying current.
Figure 12. Under-Voltage Protection (High-Side)