Datasheet
3 www.fairchildsemi.com
74LVX541
AC Electrical Characteristics
Note 4: Parameter guaranteed by design. t
OSLH
|t
PLHm
t
PLHn
|; t
OSHL
|t
PHLm
t
PHLn
|.
Capacitance
Note 5: C
PD
is defined as the value of the internal equivalent capacitance which is calculated from the operating current consumption without load.
Symbol Parameter
V
CC
T
A
25 CT
A
40 C to 85 C
Units Conditions
(V) Min Typ Max Min Max
t
PLH
Propagation Delay 2.7 6.1 11.3 1.0 13.5
ns
C
L
15 pF
t
PHL
Time 8.6 14.9 1.0 17.0 C
L
50 pF
3.3 0.3 4.7 7.0 1.0 8.5 C
L
15 pF
7.2 10.5 1.0 12.0 C
L
50 pF
t
PZL
3-STATE Output 2.7 7.1 13.8 1.0 16.5
ns
C
L
15 pF
t
PZH
Enable Time R
L
1 k
9.6 17.3 1.0 20.0 C
L
50 pF
R
L
1 k
3.3 0.3 6.8 10.5 1.0 12.5 C
L
15 pF
R
L
1 k
9.3 14.0 1.0 16.0 C
L
50 pF
R
L
1 k
t
PLZ
3-STATE Output 2.7 11.6 17.9 1.0 20.0
ns
C
L
50 pF
t
PHZ
Disable Time 3.3 0.3 10.7 15.4 1.0 17.5 R
L
1 k
t
OSLH
Output to Output 2.7 1.5 1.5
ns
C
L
50 pF
t
OSHL
Skew (Note 4) 3.3 1.5 1.5
Symbol Parameter
T
A
25 CT
A
40 C to 85 C
Units
Min Typ Max Min Max
C
IN
Input Capacitance 4 10 10 pF
C
OUT
Output Capacitance 6 pF
C
PD
Power Dissipation Capacitance (Note 5) 19 pF
Average operating current can be obtained by the equation: I
CC(opr.)
C
PD
x V
CC
x f
IN
I
CC
8 (per bit)