Programmers Manuals
Section 5: Operations
6/08 78 51195 Rev. 1
Defining the Function Keys, Continued
KEY Name DESCRIPTION
F1
Void Box Deletes the last processing record of the current product, removing that data
from the DataBank database
− Resets the Box and Pallet Serial Numbers to the values they had
before the last box label was printed.
− Pallet and Product Total counts and weights are also reset to the
values they had prior to the last box label print.
Delete confirmation message Cannot be Deleted message
F2
Reprint Re-prints the selected label type. The selected label type is determined by
the
green caption of the F3 key.
− If it reads Box, the last box label is
reprinted.
− Otherwise the last pallet label is
reprinted.
− Reprints are not allowed on voided
box or pallet labels, and cannot be performed unless the label has
been printed at least once since the product was selected.
9 See the Service & Maintenance section for the complete list of Messages and Popups.
Pressing the Right
Arrow button
activates
the
Green F-Ke
y
s.