4.2.9. Other Data String Customization, Continued
Window Name Description
CONFIGURE OUTPUT,
CONTINUED
[Port] Settings
Tab
Control Signals
DSR (Data Set Ready) –
A control signal that indicates the
device is ready to transmit data.
CTS (Clear To Send) –
A control signal used to notify the
device that it has line control.
Load Tab
Selects a preconfigured data protocol based on the scale manufacturer
selected.
Select this item first when configuring an output.
Press the
OK
button to load the data protocol selected.
DEFAULT DATA PROTOCOLS
Fairbanks
<STX><A><B><C><GGGGGG><TTTTTT><CR>
Toledo
<STX><A><B><C><GGGGGG><TTTTTT><CR>
Cardinal
<CR><P><WWWWWW><m><SP><U><SP><g><SP><SP><ETX>
Weightronix
< ><M><WWWWWW>< ><U><CR><LF>
Condec
<STX><P><WWWWWWW><U><G><M><CR>
** See
Appendix III
for more formatting information.