Owner manual
After the Unirail is physically installed, install the digital weight indicator
per the appropriate service manual.
1. Attach the cable from the Unirail splice tube to the weight indicator as
follows:
Cable leads
Green + Excitation
Black - Excitation
White + Signal
Red - Signal
Shield
2. Attach a length of 18 gauge wire from the scale structure to a
suitable ground.
50019 12 03/12 - Rev. 8
G.
Wiring
+EX
-EX
+SIG
-SIG
SHLD
LOADCELL #2
E1
E2
+EX
-EX
+SIG
-SIG
SHLD
E3
E6
E7
E8
E9
LOADCELL #1
INNER
SHIELD
OUTER
SHIELD
R1
R2
NOTE:
LOADCELL CABLE LENGTH MUST BE IDENTICAL.
+EX (GREEN)
-EX (BLACK)
-SIG (RED)
+SIG (WHITE)