6.1. CLEANING
• Wipe the scale assembly with a damp cloth using water only.
─ Do not spray cleaners onto scale indicator.
─ Do not wash-down with a pressure cleaner or water hose.
─ Do not allow water or liquids to drip onto scale indicator.
6.2. ERROR MESSAGES
Error Description Solution
ERR 1 Weight exceeds scale capacity Remove weight from scale.
ERR 2 Scale is Overloaded. Remove weight from scale. If no
weight is on scale. contact a
Fairbanks service representative.
ERR 3 or 7 Load cell signal is too low or too
high.
Contact a Fairbanks service
representative.
ERR 4 Out of Zero range. Contact a Fairbanks service
representative.
Weight is unstable.
Stabilize the weight on the scale.
Excessive vibration on floor.
Contact a Fairbanks service
representative.
LobA Battery voltage is low. Recharge battery.
LL _ _-- Out of level Move pallet jack to a level surface.
6.3. TROUBLESHOOTING
No power No power to indicator
Place Battery on
recharger.