Appendix IV: Continuous Output Data Streams
01/12 66 50647 Rev. 9
A. FORMAT: FAIRBANKS COMPUTER (FBPUTR), CONTINUED
Character 1 2 3 4 5 6 7 8 9 10
Data String STX 4 y x x x x x x ETX
x = weight
y = Second digit of a id code i.e. 4y where y= 0, 1, 3, or 4.
40 = Gross lb, oz, lb-oz, ton, or gallons
41 = Net lb, oz, lb-oz, or ton
43 = Gross kg or grams
44 = Net kg, grams, or gallons
Underload condition data stops transmitting.
Overload condition data is transmitted as the id followed by dashes.
Leading zeros are suppressed.
B. 4. FORMAT : CONSOLIDATED CONTROLS (CONCON)
Character 1 2 3 4 5 6 7 8 9 10
Data String STX x x x x x x U E CR
x = Displayed weight; Gross or Net
U = Units selected
L = pounds
K = kilograms
O = ounces
G = grams
T = tons or gallons
E = Error flag
M = motion
O = underload or overload
Space = no errors
Leading zeros are suppressed.