Owner's manual

Appendix IV: Continuous Output Data Streams
01/12 65 50647 Rev. 9
A. FORMAT: FAIRBANKS COMPUTER (FBPUTR), CONTINUED
A.2. STATUS WORD B
A.3. STATUS WORD C
BIT NO. DESCRIPTION
0 Gross = 0 Net = 1
1 Positive = 0 Negative = 1
2 In Range = 0 Overcapacity = 1
3 No Motion = 0 Motion = 1
4 Lb = 0 Kg = 1
5 Always Logic = 1
6 Normal = 0 Power-up = 1
7 Parity Bit
1 DESCRIPTION
0 Always Logic 0
1 Always Logic 0
2 Always Logic 0
3 Normal = 0 Print Switch Pushed in = 1
4 Always Logic 0
5 Always Logic 0
6 Normal = 0 Keyboard Tare = 1
7 Parity Pit