Owner's manual
Section 3: Programming
01/12 44 50647 Rev. 9
3.5.1. I/O MENU DESCRIPTIONS, CONTINUED
TARGET MENU
PROMPT CHOICE(S)
tArgEt
Used for programming weight values associated with setpoint-relays.
Target 1 = relay 1 and Target 2 = relay 2, through rest of programmed
setpoints.
The number of targets will vary depending on number selected during
initial setup. Modifications should be performed with caution.
The Setpoint mode determines the target function, and targets should
be programmed accordingly.
SEtPnt MODE
Target Assignment
PROMPT CHOICE(S)
SPCont
Target 1 thru X (where X is the total number of setpoints) are the
programmed number of setpoint relays.
Single-value relays that energize when their assigned weight value is
reached or exceeded.
These relays, as a group, are manually controlled by the START and
STOP front panel keys.
No Autoprint available in this mode.
SPChEC
In the Check Weigh mode, Target 1 is the UNDER range setpoint-
Relay 1.
It is on-active if the weight is equal to or below its assigned weight
value.
Target 2 is the OVER range setpoint-Relay 2.
It is Active when the weight is equal to or above its assigned weight
value.
The ACCEPT range is the weight between UNDER and OVER.
It is selected to operate either the Gross or Net modes.
NOTE:
The legends for UNDER, ACCEPT, and OVER show on the large display
when its associated weight value is active.
There is not a relay output for the ACCEPT range.
When using the
SPCont or SPChEC modes the relays respond to the
absolute value displayed (+/-) in the Gross mode and to the positive value
displayed in the
Net mode.