Owner's manual

Section 3: Programming
01/12 42 50647 Rev. 9
3.5.1. I/O MENU DESCRIPTIONS, CONTINUED
PROMPT COMMENT(S)
Port A
Port A has available selections of the following:
UnUSEd - no outputs
Printr - printer output
Contin - continuous output
noALog, AnALog
Used to turn on or off the 4 - 20MA output.
noALog = Off
AnALog = On
Protob
Protocol setting for Port A choices include the following:
bAUd 9600, 600, 1200, 2400, and 4800
ChAr 8 and 7
PAritY nonE, odd, and EuEn
tArgEt
Conditional, if setpoints are selected in Port B.
1. Press
ENTER to adjust the Setpoint Target Weight Menu.
The large display shows the Current Target Weight Value
associated with the Target Number, as shown in the small
display.
The
SCROLL key toggles through available Setpoint Relays
(Targets).
2. Enter a new Target Weight Value with the numeric keypad.
3. Press
ENTER to accept the new weight value and advance to the
next available target.
Port b
Port b can be configured for the following:
UnUSEd - no outputs
* SEtPnt - Setpoint modes
* PoLL or PoLL id - computer output
Printr – printer
Contin - continuous output
Poll
Used for Demand Output to a computer.
When the instrument receives an upper-case "W" followed by a
carriage return ("W", "Cr") from the PC, a data stream transmits.
See Appendix VII for ASCII Chart.
Poll id
Use this demand mode when a specific instrument ID is required.
Setup by entering the required ID's decimal equivalent.
See Appendix VII for ASCII Chart.