Owner's manual

Section 3: Programming
01/12 41 50647 Rev. 9
3.5.1. I/O MENU DESCRIPTIONS, CONTINUED
PROMPT COMMENT(S)
LoSEt
Sets the weight value associated with 4mA.
Usually "0".
1. At the LoSEt prompt, press ENTER.
2. Use the numeric keypad to enter desired weight value.
3. Press ENTER.
hiSEt
Associated weight value of 20MA.
Usually the capacity of the scale.
1. Press ENTER at the hiSEt prompt.
2. Use the numeric keypad to enter the desired weight value.
3. Press ENTER.
4 AdJ
Press ENTER to display a current number representing the 4mA Output.
See note on key functions.
20 AdJ
Press ENTER to display a current number representing the 20mA
Output.
See note on key functions.
AgtESt
LP4 - TO - LP22.
Press ENTER to perform an analog test.
4mA thru 22mA will be output momentarily in 2mA steps.
When adjusting either 4mA or 20mA, the following numeric keys increase
or decrease the reference value in the fashion that follows.
Increased by: Decreased by:
9 10,000 4 10,000
8 1,000 3 1,000
7 100 2 100
6 10 1 10
5 1 0 1
ConoPt
Used for Continuous Output.
Choices include the following:
3052r FbStd FbPUtr troniC ConCon
ProtoA
Protocol setting for Port A choices include selections for the following:
bAUd 9600, 600, 1200, 2400, and 4800
ChAr 8 and 7
PAritY nonE, odd, and EuEn