Owner's manual

Section 1: General Information
01/12 13 50647 Rev. 9
1.3. ACCESSORIES, CONTINUED
1.3.8. ACCESSORY 2860 SAFE AREA DATA CONVERTER
(20523)
This accessory is service programmable and configurable for RS232 or 20mA
data outputs.
This accessory can also be configured to provide a 4-20 ma analog output.
Enclosure: NEMA 4; Fiberglass
4 -20 ma Specifications: 16 bit resolution (+/- .01 integral linearity)
Current loop voltage compliance: 7vdc minimum to 40vdc maximum (typical
voltage = 24vdc)
Full scale settling time: 8msecs
Output impedance: 25 meg
Alarm current: 3.5 to 24 mA (underload/overload conditions)
Offset @ 25 degrees C; +/- .1% of full scale
Offset drift: +/- 25ppm of full scale per degree C
Total output error: 20mA @ 25 degrees C: +/- .2% of full scale max
Total output drift: +/- 50ppm of full scale per degree C-max
1.3.9. ACCESSORY 2875 INTRINSICALLY SAFE
INTERCONNECTION CABLE (21737)
This is the only approved cable for interconnecting the Accessory 2802, and
for connecting to the Model 2800 to the Accessory 2850.
Specifications: 2 pair - 16AWG; 0.48" O.D.
CAUTION
The 4-20ma accessory is a passive device!
The power is to be supplied by others, and MUST
 BE
a DEDICATED and an ISOLATED
p
ower su
pp
l
y
.