User Manual

Section 1: General Information
02/13 11 51315 Rev. 1
1.4. SPECIFICATIONS, CONTINUED
1.4.5. OUTPUTS
PORT 1
Bidirectional Serial Port. Settings include OFF, RS232, and
RS485. RS232 has 30+ updates a second
PORT 2
Port 2 is used to interface to the PC2255 program,
OR,
Provide 20 mA passive, RS 232, or RS 485.
1.4.6. PC2255
Computer software utility program is available for download using the Fairbanks Intranet.
PC2255 is required for setting certain aspects of programming, such as custom Units and custom
ticket formatting.
1.4.7. POWER REQUIREMENTS
117 volts AC +/- 10 %
220 volts AC +/- 10 %
< 0.2 volts AC between Neutral and Ground
1.5 watts maximum
The FB2255 is designed to operate from 80 to 260 volts AC, 50 to 60 Hertz
1.4.8. OUT OF RANGE WARNINGS
HiCAP
Scale input is over capacity
- - - - - - -
Displayed weight exceeds 6 digits
1.4.9. ENVIRONMENT
Temperature
-10ºC to + 40ºC (+14ºF to + 104ºF)
Storage Temp.
-40ºC to + 60ºC (-40ºF to + 140ºF)