User Manual

Section 4: User Operations
08/12 30 51300 Rev. 1
4.6.2. Setting Up PLU Keys 0 thru 999
1. Set up the Piece Weight as in Section 4.5. Sampling Operation.
2. Press and will flash on the display.
3. Press the numeric keys to select PLU number, with a three (3) digit maximum.
4. Press to save your setting, will stop flashing on the display.
5. If the entry needs to be cleared press the key.
EXAMPLE
1. Press + to enter a Piece Weight as 0.5 pounds.
2. Press .
flashes on the display.
3. Press key.
PLU indicator displays 555.
flashes on the display.
4. Press key.
5. After the beep, the Piece Weight for
PLU 555 is stored as 0.5 pounds.
NOTE: If there is no data input in thirty (30) seconds, the scale exits the PLU
Setting Mode and returns to the Weight Mode.