User Manual
Section 4: User Operations
08/12 29 51300 Rev. 1
4.6. PLU (PART LOOK UP) OPERATION
PLU (Part Look Up) is a memory lookup number that includes the Piece Weight
and Tare Weight.
– The scale can store up to 999 PLU items into memory.
– When any PLU is activated, the scale replaces the current Piece Weight
and Tare Weight with the PLU selected from memory.
4.6.1. Setting Up PLU Keys 1 thru 9
1. Set up Piece Weight as described in Section 4.5. Sampling Operation.
2. Press .
– flashes on the display.
3. Select a
PLU Number from the Direct PLU keys.
4. Press to save the setting.
– stops flashing.
5. If the entry needs to be cleared, press the key.
EXAMPLE
1. Press + to enter a Piece Weight as 0.5 pounds.
2. Press key.
– flashes on the display.
3. Press key three (3).
– flashes on the display.
4. Press key, after the beep, the Piece Weight for PLU 3 is now set as 0.5
pounds.
NOTE: If there is no data input in thirty (30) seconds, the scale will exit the PLU
Setting Mode and returns to the Weight Mode.