Owner's manual

Section 4: Assembly
02/2011
12 51260 -- Rev. 1
E. Insert the ā€œSā€ hook (#3) (Figure 4-2) through the eyelet of the load cell linkage
cable adapter.
F. Slide the ā€œSā€ hook bottom into the top hook on the pull rod.
4.3. Installing the instrument
A. Locate the in-line phone plug adapter (#4) and connect the phone plug on the
end of the load cell cable and the phone plug on the end of the instrument
cable into the adapter. See figure 4-3.
B. Locate the cable tie mount (#5) in the bracket approximately as shown.
Secure the load cell cable in place with wire tie (#6). Insure cables do not
touch live portion of the load cell. See figure 4-3.
Figure 4-2