MERCHANDISER REFRIGERATORS AND FREEZERS Manual for installation, use, and maintenance
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 Contents 1 RECEIVING AND INSPECTING THE EQUIPMENT .......................................................................... 3 2 SPECIFICATIONS........................................................................................................................... 4 3 DIMENSIONS ............................................................................................................................... 6 4 INSTALLATION ...................
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 1 RECEIVING AND INSPECTING THE EQUIPMENT Up on receiving your new Fagor Refrigerator, check the package and the machine for any damages that may have occurred during transportation. Visually inspect the exterior of the package. I f damaged, open and inspect the contents with the carrier. Any damage should be noted and reported on the delivering carrier’s receipt.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 2 SPECIFICATIONS REACH IN MERCHANDISERS AND FREEZERS, GENERAL SPECS Temperature Operation Model FM-10 FM-16 Capac. (Cu. Ft.) #of Shvls Set Point Cut in 10 4 0°C/32°F 5°C/41°F 4 0°C/32°F 16 Pressure in Suction Line* SuperHeat** BTU Ref. Amount Ref. Type Ship Weight 10-16 PSIG 7°C/13°F 1400 9.8 oz R-134a 203 5°C/41°F 10-16 PSIG 7°C/13°F 1800 9.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 REACH IN MERCHANDISERS AND FREEZERS, ELECTRICAL SPECS Models FM-10 FM-16 FMD-23 FMD-37 FMD-49 FM-16F FMD-23F HP 1/4 1/4 1/4 1/3 1/3 3/4 3/4 Voltage 115 220 115 220 115 220 115 220 115 220 115 220 115 220 Amp. Max. 5.8 3.1 5.8 3.4 5.8 3.5 6.9 3.9 6.9 4.5 8.8 4.5 8.8 6.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 3 DIMENSIONS FM-10 FM-16 www.fagorcommercial.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 FMD-23 FDM-49 www.fagorcommercial.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 FMD-47 SD FMD-37 SD www.fagorcommercial.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 4 4.1 INSTALLATION UNCRATING Remove the outer packaging. Cut the 4 clamps that hold the refrigerator to the skid. Lift the unit off the skid. If machine was laid down during this operation, remember to leave the cabinet up right for 24 hours before connecting to power source. 4.2 LOCATION Units represented in this manual are intended for indoor use only.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 4.3 DATA PLATE The data plate is located inside the cabinet, near the top front, left corner. Under no circumstances should the data plate be removed from the unit. The data plate is essential to identify the particular features of your machine and i t is of great benefit to installers, operators, and maintenance personnel.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 4.4 ELECTRICAL CONNECTIONS Refer to the amperage data in this manual, or on data plate, and your local code or the National Electrical Code to be sure unit is connected to the proper power source. Verify correct incoming voltage according to the Data Plate information. Do not, under any circumstances, cut or remove the ground prong from the power cord. Fagor units must be properly grounded.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 5 5.1 OPERATION ELECTRONIC CONTROLLER CAREL CONTROL After connecting your unit, turn ON rocker switch located next to the controller. The display will light up showing the temperature inside the unit. Also, the compressor and fan icons will flash for a period of three minutes. After this delay the unit will start cooling. Verify you don't have any alarms on the temperature controller.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 Changing the Set Point of the temperature on the controller The unit comes with a factory default set point ( 32°F Refrigerators). These set values will make the unit perform at its maximum capacity. Therefore, it is not recommended to change the set point. If set point needs to be changed, follow the next steps. 1. Push the SET button for one second. You should see a flashing number. Release the button. 2.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 CAREL CONTROL (IR33+) The operating parameters can be modified using the front keypad. Access differs depending on the type: set point, frequently-used parameters (F) and configuration parameters (C). The type of parameter is specified in the table of parameters. Access to the configuration parameters is protected by a password for the configuration parameters that prevents unwanted modifications or access by unauthorised persons.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 Setting type C parameters Type C parameters include the type F parameters plus all the other control parameters. Procedure: 1. Press Prg/Mute one or more times to return to the standard display; 2. Press Prg/Mute for more than 3 seconds (if an alarm is active, the Buzzer is muted): the display will show the code PS (Password) and The number 0; 3. Press UP/DOWN and enter the password: 22. Press Set, the display Shows parameter/2; 4.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 6 MAINTENANCE Stainless Steel Care and Cleaning Proper cleaning of stainless steel requires soft cloths or plastic scouring pads. Never use steel pads, wire brushes, or scrapers! Cleaning solutions need to be alkaline or non-chloride cleaners. Any cleaner containing chlorides will damage the protective film of the stainless steel. Chlorides are commonly found in hard water, salts, house hold and industrial cleaners.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 If you keep the Condenser clean, you will minimize your service expense and lower your electrical costs. Failure to maintenance clean condenser coil can initially cause high temperatures and excessive run times. Continuous operation with dirty or clogged condenser coils can result in compress or failures. This will not be covered under warranty. Neglecting the condenser coil cleaning procedures WILL VOID YOUR WARRANTY.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 Units installed in a humid environment will produce large amounts of water in the drain pan. This is NOT a malfunction of the unit. It is the customer’s responsibility to clear the drain pan as necessary to avoid puddles of water underneath the unit. Do not store open containers with liquids inside the unit. This will increase the amount condensation inside and outside of the unit, and the evaporator coil will freeze up.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 7 WIRING DIAGRAMS FM-10 www.fagorcommercial.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 FM-16 / FMD-23 www.fagorcommercial.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 FM-16F / FMD-23F www.fagorcommercial.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 8 TROUBLE SHOOTING Follow the next steps before requesting warranty service. Failure to do so, may result in service charges for you and may void your warranty: 1) Refrigerator doesn’t work: a. Check that the machine is still connected. b. Check that the ON/OFF button is in the ON position. 2) Refrigerator doesn’t reach temperature: a. Check that the thermostat is not in OFF position. b. Check that the machine is not in the defrost cycle. c.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. Feb. 2014 9 WARRANTY AS OF APRIL 1, 2014 Three Years Parts & Labor Warranty: Fagor Commercial, Inc.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 Proper Maintenance and Operation: The Equipment must be properly maintained and operated in accordance with Fagor’s maintenance and operating procedures. All service, labor and parts must be acquired from Fagor or its authorized service representative for the User’s area.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 Terms & Conditions Prices & Specifications: Fagor reserves the right to change the prices and specifications of the equipment and/or material without notice. Prices are FOB Fagor warehouses. All orders are subject to acceptance by Fagor Commercial, Inc. Terms: All orders are subject to credit approval. All Invoices not paid within the specified terms will be subject to a 1.5% per month delinquency charge.
MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015 Fagor Commercial, Inc. 13105NW 47thAve Miami, Fl. 33054 Tel:(305) 7790170 Fax:(305)7790173 1-866-GO-FAGOR www.fagorcommercial.com www.fagorcommercial.