Operation Manual

THE INDUCTION HOB
Technical training
- 29 -
CU3-INDUCTION-003UK-10/05
IX3
10 - THE IX3 HOBS
10.1. - Description
The hob of generation IX3 is
identified by the presence of
a mounting part that appears
under the hob, ventilation
part, and by its internal
composition of two boards
(filter and power), with the
keyboard possibly having
several various shapes,
according to the brand and
model.
The IX3 operating principle is the same as IX1 and 2. When
two inducers of the same generator are used
simultaneously, the power is distributed by switching relays.
IX3 production has stop in 2005 and has been replaced by version IX4000.
Standby consumption is under 3.5 Watts.
Filter board
230V~
Earthing screw,
its presence is
imperative
Fan power supply
Rear temperature
sensor
Front temperature
sensor
Keyboard connector
Bipolar
transistors
Diode rectifier
Distribution relays