Operation Manual

THE INDUCTION HOB
Technical training
- 13 -
CU3-INDUCTION-003UK-10/05
INSTALLATION
5.3. - IX6 ventilation
To allow good ventilation in several conditions, the IX6 hobs use a new bottom cabinet. The front holes
cannot be shut by the worktop. (This new cabinet is also used for IX4000 models since June 2005).
¾ Over a furniture with door or drawer
The installation shall guarantee fresh-air inlet at the rear and
outlet at the front
¾ Over an oven of the same brand
The installation should guarantee fresh-air inlet at the rear and
outlet at the front.
¾ Over an oven of other brand
The installation must guarantee fresh-air inlet at the rear.
The front outlet must 4mm minimum and the oven must be insulated
from the hob (Distance 5cm minimum
Over an oven of other
brand: The installation should
guarantee fresh-air inlet at the
rear and outlet at the front,
and the oven shall be isolated
from the hob
Over an oven of same
brand: The installation should
guarantee fresh-air inlet at the
rear and outlet at the front.
Over a dishwasher : It is
necessary to cover the
dishwasher top with an
insulating plate supplied
together with the hob. A
minimum fresh-air inlet shall
be provided.
Cutting of 40cm
2
in one
of the furniture side
Insulating plate
Oven in down position Oven in up position