User Manual
3
Installation Instructions
Turn off the water at the supply before beginning the
installation.
Remove the caps from the plaster shields. Cut the
plaster shields 1 mm (1/16”) from the surface of the
finished wall. Seal around the plaster shields with
waterproof sealant.
Use a 27 mm deep socket wrench to remove the flush
insert.
Use a 17 mm deep socket wrench to remove the plug
from the spout port.
Install the cartridge and anti twist device to the
cartridge housing. Make sure that the cartridge is
oriented as shown in the diagram.