Owners Guide

23
GREASE FILTER
The lter must be cleaned every 2 months of operation, or more
frequently for particularly heavy usage, and can be washed in a
dishwasher.
CLEANING METAL SELF-SUPPORTING GREASE FILTER
Open the lighting unit by pulling on the notch.
Remove the lter one by one pushing it towards the back side
of the hood unit and simultaneously pulling downwards.
Any kind of bending of the lter has to be avoided when wash-
ing it. Before tting it again into the hood make sure that it is
completely dry.
When tting the lter into the hood pay attention that they are
mounted in correct position the handle facing outwards.
Replace the lighting unit.
No water must be present in lter before installing.
ACTIVATED CHARCOAL FILTER
This cannot be washed or regenerated, and must be changed ap-
proximately once every 4 months, or more frequently in the case of
particularly intensive use.
CHANGING
Open the light unit.
Remove grease lter.
Remove the saturated Activated Charcoal Filters, as indicated (A).
Fit the new Filters FILTER1 or FILTER 1LL, as indicated (B).
Fit the anti-grease lter and the Light Unit back into position.
HOOD LIGHTING UNIT
• For replacement contact technical support ("to purchase con-
tact technical support").
CEILING LIGHTING DIFFUSER
G9 self-ballasted led lamps - listed in accordance with ul 1993/
nmx-j-578/1-ance/csa c22.2 No. 1993
Replace the lamp with a new one of the same type, making sure
that you insert the two pins properly into the housings on the lamp
holder.
MAINTENANCE