Frominsidethehood,removethe
cover from the Wiring Box 2 by
removingthetwoscrews.
Breakthehole intheWiringBox
for passing the cables from the
remoteblower.
FromInsidetheHoodconnectthe
cabletotheWiringBOX2.
ConnectthecablefromtheRemoteBlowerwiththetwo
wireinsidetheWiringBoxbytwist-on type wire connec-
torandmatchingthecolor.
Replacetheeldwiringcompartmentcover.
ChecktheWiringDiagram.