Installation Instructions
Version 6/12 - Page 15
PRODUCT INSTALLATION
- Push the side covers into place on the
mounting brackets on top of the counter and
lock them in place (FIGURE 29)
- Connect the appliance to the electric power
supply (see the next page)
- Push the On / Off button on top of the hood
- The hood vent will rise and the fan will turn
on
- Place the grease lters into the unit by
pressing them downwards and pushing the
top of the lter towards the unit until it clips in
place. Press the on / off button on top to make
sure the unit goes down. (FIGURE 30)
- Connect 6" round ducting to the unit.
FIGURE 29
FIGURE 30
REMOTE BLOWER INSTALLATION
- When using the remote blower, a connection
plate must be installed on the hood instead of
a blower box. It can be mounted to the front
or back of the unit.
- If the connection plate is on the front of the
unit, then the ducting can only come out of the
front
- If the connection plate is on the back of the
unit, then the ducting can only come out of the
back
- The connection plate is installed using 4
screws as shown in FIGURE 31
- The cover plate is installed onto the housing
on the opposite side of the connection plate
(FIGURE 32)
- The remote blower is connected to the
downdraft unit with an additional control cable.
See the installation instructions for the remote
blower. The control cable will be connected in
the wiring box of range hood.
- Use 10" round ducting to connect the remote
blower.
FIGURE 31
FIGURE 32