Data Sheet
dbl_d10stph.pdfIssue23.11.2018 · Klaus Faber AG · Lebacher Straße 152 – 156 · 66113 Saarbrücken · Germany · Phone +49 681 9711-0 · Fax -289
LAN cable FABER®
dataline 1000 STP (S-FTP)
CPR-performance: Dca
Specification/Standard: ISO/IEC 11801, EN 50173, EN 55022, EN 50288-4-1, EN 50167, EN 50169
Conductor material: copper, bare
Insulation: foam-PE
Screen over stranding unit: foil
Screen over strand: Cu-braid, tinned
Sheathing material: FRNC-compound HM2
Colour outer sheath: orange RAL 2004
Flame-retardant: VDE 0482-332-1-2/IEC 60332-1-2
Smoke density: DIN EN 61034/IEC 61034
Halogen-free: DIN EN 50267/IEC 60754
Permitted outer cable
temperature, fixed:
-20 - +70 °C
Permitted outer cable
temperature, in motion/
during installation:
0 - 50 °C
Bending radius, fixed
installation:
4 x DA
Bending radius, moving
application:
8 x DA
Impedance: 100 Ohm
Velocity factor (NVP): 0,78 v/c
Category: 7+
Segregation class (EN
50174-2):
d
FABER® dataline 1000 FABER® dataline 1000 duplex
Maximum operating capacity: 56 nF/km 56 nF/km
Test voltage: 2,5 kV 2,5 kV
Core identification: colours acc. to IEC 60708 colours acc. to IEC 60708
Application: For the connection of IT system units in the desktop area (tertiary sector), e.g. between floor distributors
and workstation up to 1000 Mbit/s (category 7+). It fully complies with the electromagnetic compatibility requirements
(EMC) of European Standard EN 55022 and the guidelines of the European Postal Administration. Furthermore, the
copper braiding ensures perfect matching with screened connectors.
The products and information presented here are for technical calculation only. They are subject to technical progress and in no way represent the
ability of shipment. Outer diameters are approximately.
RF-parameters