Datasheet

dbl_d10stph.pdfIssue24.03.2017 · Klaus Faber AG · Lebacher Straße 152 – 156 · 66113 Saarbrücken · Germany · Phone +49 681 9711-0 · Fax -289
LAN cable FACAB dataline
1000 STP (S-FTP)
specification/standard: ISO/IEC 11801, EN 50173, EN 55022, EN 50288-4-1, EN 50167, EN 50169
conductor material: bare copper
insulation: foam-PE
screen over stranding unit: foil
screen over strand: Cu-braid, tinned
sheathing material: FRNC-compound HM2
colour of outer sheath: orange RAL 2004
flame retardant: VDE 0482-332-1-2/IEC 60332-1-2
smoke density: DIN EN 61034/IEC 61034
halogen free: DIN EN 50267/IEC 60754
max. operating temperature,
fixed:
-20 - +70 °C
temperature, moved/during
installation:
0 - 50 °C
bending radius, fixed
installation:
4 x DA
bending radius, moved
application:
8 x DA
impedance: 100 Ohm
velocity factor: 0,78 v/c
category: 7+
segregation class (EN
50174-2):
d
FACAB dataline 1000 FACAB dataline 1000 duplex
operating capacity: 56 nF/km 56 nF/km
test voltage: 2,5 kV 2,5 kV
core identification: colours acc. IEC 60708 colours acc. IEC 60708
Application: For connection of IT system units in the desktop area, between workstations and as riser cable up
to 1000 Mbit/s (category 7+). It fully complies with the requirements to electromagnetic compatibilty (EMC) of the
European Standard EN 55022. Additional the copper braiding ensures perfect matching with screened connectors.
7+
The products and information presented here are for technical calculation only. They are subject to technical progress and in no way represent the
ability of shipment. Outer diameters are approximately.
RF-parameters
f, MHzattenuation,
nominal
value,
dB/100 m
attenuation,
typical
value,
dB/100 m
NEXT, dB,
nominal
value
NEXT, dB,
typical
value
PS-NEXT,
dB, typical
value
ELFEXT,
dB/100
m, typical
value
PS-
ELFEXT,
dB/100
m, typical
value
PS-ACR,
dB, typical
value
Return
loss, dB,
typical
value
1 2 1,9 80 100 97 90 87 95,1 27
10 5,7 5,5 80 100 97 90 87 95,1 30

Summary of content (2 pages)