Data Sheet

dbl_j2ysty.pdfIssue23.11.2018 · Klaus Faber AG · Lebacher Straße 152 – 156 · 66113 Saarbrücken · Germany · Phone +49 681 9711-0 · Fax -289
ISDN cable J-2Y(St)Y ... St III Bd
Conductor material: copper, bare
Conductor class: class 1 = solid
Insulation: polyethylene
Stranding unit: quads
Stranding: bunches
Screen over strand: foil
Drain wire: yes
Sheathing material: PVC
Colour outer sheath: grey RAL 7032
Flame-retardant: VDE 0482-332-1-2/IEC 60332-1-2
Permitted outer cable
temperature, fixed:
-30 - +70 °C
Permitted outer cable
temperature, in motion/
during installation:
-5 - +50 °C
Bending radius, fixed
installation:
7,5 x DA
Impedance: 100 Ohm
Insulation resistance: 5000 MOhmxkm
Coupling K1: 400 pF
Coupling K9-12: 100 pF
Maximum operating capacity: 52 nF/km
peak operating voltage: 300 V
Application: For connection of computer units, ISDN-sub-units and -devices and for data transmission. Suitable
for transmission of analogue and digital signals up to 16 Mbit/s. For installation in dry and wet rooms, on and under
plaster.
Additional information: Stranding: 4 cores twisted into star-quads, 5 star-quads stranded into one sub-unit, sub-units
layed up in layers. Core identification: The star-quads of each bunch are continuous: red, green, grey, yellow, white.
The cores within one star-quad are marked by rings: a-wire 1: without ring b-wire 1: one ring, wide spaced a-wire 2:
double ring, wide spaced b-wire 2: double ring, narrow spaced
The products and information presented here are for technical calculation only. They are subject to technical progress and in no way represent the
ability of shipment. Outer diameters are approximately.
Table: Technical characteristics J-2Y(St)Y ... St III Bd
p/n part name D
A.
[mm]
G
.
[kg/km]
Cu
.
[kg/km]
100210 J-2Y(St)Y St III Bd 02X2X0,6
GR
5,5 42 13
p/n part name D
A.
[mm]
G
.
[kg/km]
Cu
.
[kg/km]
100211 J-2Y(St)Y St III Bd 04X2X0,6
GR
7,5 66 24