Data Sheet
© 2022 · Klaus Faber AG · all rights reserved KLAUS FABER AG · Europaallee 33 · 66113 Saarbrücken · Germany · T +49 681 9711 - 0 dbl_j2ysty.pdf / Issue 02/17/2022 / page 1/2
ISDN cable
J-2Y(St)Y ... St III Bd
Application: For connection of computer units, ISDN-sub-units and -devices and for data transmission. Suitable for transmis-
sion of analogue and digital signals up to 16 Mbit/s. For installation in dry and wet rooms, on and under plaster.
Construction and technical data:
Conductor material: copper, bare
Conductor construction: Class 1 = solid
Insulation: polyethylene
Stranding unit: Four strand
Stranding: Bundle
Screen over strand: Foil
Drain wire: yes
Sheathing material: PVC
Colour of outer sheath: grey RAL 7032
Flame-retardant: VDE 0482-332-1-2/IEC 60332-1-2
Permitted outer cable temperature, xed, °C: -30 - +70 °C
Permitted outer cable temperature, moved, °C: -5 - +50 °C
Bending radius, xed installation: 7.5 x Ø
Impedance: 100 Ohm
Insulation resistance: 5000 MOhmxkm
Coupling K1: 400 pF
Coupling K9-12: 100 pF
The products and information presented here are for technical calculation only. They are subject to technical progress and in no way represent the ability of
shipment. Outer diameters are approximately.