Datasheet
dbl_rg58.pdfIssue15.07.2016 Klaus Faber AG, 66113 Saarbrücken, Lebacher Str. 152-156, Tel.: (0681) 9711-0, FAX: - 289
Coaxial cable RG 58 C/U
inner conductor: Copper, stranded, tinned
inner conductor diameter: 0,9 mm
insulation: solid PE
screen: tinned copper braiding
coverage: 93 %
outer sheath: PVC
installation temperature: 0 - 80 °C °C
operating temperature: -5 - +80 °C
impedance: 50 Ohm
capacity: 101 nF/km
velocity factor: 0,66 v/c
signal delay: 5,03 ns/m
DC-resistance inner
conductor:
36 Ohm/km
DC-resistance screen: 17 Ohm/km
test voltage: 5 kV
Application: For data- and signaltransmission in RF-bands with low losses and interferences.
The products and information presented here are for technical calculation only. They are subject to technical progress and in no way represent the
ability of shipment. Outer diameters are approximately.
Table: Technical characteristics RG 58 C/U
p/n part name R
bv.
[mm]
D
A.
[mm]
E
v.
[kWh/m]
Cu
.
[kg/km]
G
.
[kg/km]
101437 RG 58/C/U 50 Ohm SW
Outdoor
0,3 20 44
100104 RG 58 C/U 50 Ohm SW 30 5 0,23 20 38
100605 RG 58 C/U 50 Ohm SW
halogenfrei
30 5 0,23 20 38
Rbv bending radius, fixed installation
DA outer diameter
Ev combustion energy
Cu copper weight (ger)
G weight