Datasheet
dbl_h01n2.pdfIssue24.03.2017 · Klaus Faber AG · Lebacher Straße 152 – 156 · 66113 Saarbrücken · Germany · Phone +49 681 9711-0 · Fax -289
Welding cable H01N2-D/-
E acc. to EN 50525-2-81
conductor material: copper, bare or tinned
conductor construction: fine stranded class 6
sheathing material: rubber (CR) EM5
flame retardant: VDE 0482-332-1-2/IEC 60332-1-2
oil resistant: EN 60811-2-1
maximum temperature at
conductor:
85 °C
max. operating temperature,
fixed:
-20 - +85 °C
H01N2-E - cable with high flexibilty H01N2-D - cable with normal flexibility
nominal voltage Uo: 100 V 100 V
nominal voltage U: 100 V 100 V
test voltage: 1 kV 1 kV
Application: In dry, damp and wet rooms as welding cable for machine or hand operation.
The products and information presented here are for technical calculation only. They are subject to technical progress and in no way represent the
ability of shipment. Outer diameters are approximately.
current rating
operation
modus
permanent periodical
operation cycle - 5 min.
load factor 100 % 85 % 80 % 60 % 35 % 20 % 8 %
cross-section current
rating
A
10 96 97 98 102 114 137 198
16 130 132 134 142 166 204 301
25 173 179 181 196 234 293 442
35 216 226 229 250 304 384 584
50 274 287 293 323 398 508 779
70 341 360 398 409 510 655 1011
95 413 438 448 502 632 816 1266
120 480 511 523 588 745 966 1501
150 557 594 609 687 875 1137 1771
185 638 683 700 793 1012 1319 2059
.
Table: Technical characteristics H01N2-E - cable with high flexibilty
p/n part name R
l.
[Ω/km]
D
A.
[mm]
Cu
.
[kg/km]
G
.
[kg/km]
060022 H01N2-E 01X10 SW 1,91 6,9 96 122
060015 H01N2-E 01X16 SW 1,21 7,9 154 235
060023 H01N2-E 01X25 SW 0,78 9,4 240 282
060024 H01N2-E 01X50 SW 0,386 12,8 480 534
060019 H01N2-E 01X70 SW 0,272 14,2 672 716